Lighting solutions for underpasses

Lighting solutions for underpasses

Efficient LED lighting for underpasses - they should simultaneously increase the well-being and safety of people and be as resistant as possible to extraneous influences.

From a technical point of view, underpass lighting is subject to particularly high demands due to various factors. Only a few luminaires meet the requirements for continuous use, uniform illumination, the highest possible energy efficiency and high resistance.

To increase the service life of underpass lighting, the use of robust and durable luminaires that are designed to better withstand vandalism or graffiti is a good option.

But finding the right solution for underpass lighting is also important for a sense of personal safety. A sense of insecurity quickly arises in the confining conditions of an underpass. A well-lit underpass can counteract this and increase people's subjective sense of security.


To the products
img

Which luminaires are suitable in underpass lighting?

It is important that the underpass light is durable and resistant. Only thanks to robust materials can this be ensured.

Designplan Lighting stands for durable luminaires. The extra-durable products feature rugged metal housings that can withstand forces of up to 250 joules - over 12 times more than a conventional IK10 luminaire fixture (20 joules).

  • High intrusion protection thanks to tamper-resistant screw
  • Corrosion resistance and impact/scratch resistance due to durable surface with polyester powder coating
  • Removable equipment racks allow easy maintenance and cost-efficient technology upgrades
Download product overview

State-of-the-art lighting technology for more safety and efficiency

There are several factors to consider when planning and implementing underpass lighting. These include:

  • Vandalism in the form of graffiti and vandalism
  • The surrounding lighting level
  • glare control
  • Rugged media channels for flexible replication of tunnel courses

An optimal light distribution, energy efficiency and contemporary forms of control with built-in motion detectors are additional parameters that are not neglected even in extra robust housings with impact-resistant covers. Designplan offers fine-tuned development processes and measurements, e.g. with a photogoniometer, for reliability in the later planning process.

Thanks to the latest lighting technology, we can guarantee these parameters and offer individual solutions for various underpass lighting systems.

img

Exceptional IK classification

The IK-­Klas­si­fi­zie­rung is an in­ter­na­tio­na­l standard, which specifies the suitability of electrical operating equipment for different applications. The IK-­Code (In­ter­na­tio­nal Stan­dard IEC 62262:­2002 and IEC 60068-­2-­75:­1997) klas­si­fi­zes the protection ge­gen me­cha­ni­s force­ein­wir­kung, the shock­fes­tig­tig­degree.

The test with a pen­del­ham­mer according to EN 60068-­2-­75 er­mög­makes it possible for Designplan to post­fully­draw­bar the impact­fes­tig­ness­of the luminaires. Designplan believes that the of­fi­ci­el­le en­de of the ska­la (20Joule/IK10) is not an­adequately­sufficient, to meet the requirements of the me­cha­ni­s in many pro­jec­ts. For example, Designplan has increased the ska­la above­half to 250 joules (IK20) and can also prove this with the "pendulum hammer test". Products from Designplan thus proven to have an IK degree of protection between IK10 and IK20.


Products for your underpass lighting

Whether for subway stations, pedestrian underpasses, or covered areas, lighting that is individually tailored to local circumstances is necessary to keep people safe and minimize operating and maintenance costs.

With a streamlined and targeted product range in the field of lighting for underpasses, our expertise as well as our customer-specific consulting, we will be happy to help you implement your new underpass lighting.

Duomo GDU3

Surface mounted luminaire with high resistance to mechanical impact. Ideal for use in underpasses, public areas and parking garages.

Monitor GD855

Simple design and high resistance. Especially suitable for use in underpasses and parking garages.

Are you planning the lighting of an underpass? Our experts are happy to help

image of Public Lighting Team

Public Lighting Team

Sales Smart City and Light Contact

Advantages of perfectly matched underpass lighting

More security
In underpasses, good lighting increases people's subjective sense of safety
Efficient maintenance
thanks to removable gear trays and tamper-proof screws
Corrosion resistant & robust
Through the use of robust materials and polyester powder coatings.

3 good reasons to opt for modern LED underpass lighting

Energy efficient
LED underpass lighting reduces power consumption and thus electricity costs, despite continuous use.
Durable
With robust materials and special safety devices, vandalism is prevented and longevity of the luminaire is guaranteed.
Safe
Thanks to the lights, underground paths and tunnels are illuminated brighter and more evenly than before. Thus, the feeling of safety is naturally increased.

Practical example Wettingen

You might also be interested in

Current topics in public lighting

The use of outdated or insufficient lighting in the area of underpasses can not only reduce safety enormously, but also drive up the cost of energy unimaginably.
By choosing the right luminaire, these areas in particular can be drastically improved.